Periodic Condition Assessment Contracts
Many of the equipment don’t undergo Condition Monitoring just because, maintaining the trend of readings is not needed in those cases. Such equipment undergoes condition assessment every time. Maintaining the health of such equipment is essential too, and that makes us adopt Periodic Condition Assessment of such equipment to maintain a healthy condition.
Periodic Condition Assessment is actually a Periodic Health Assessment. The CAss is done quarterly, half-yearly or yearly for such equipment.
Following is the list of our services,
- Periodic CAss of Compressed Air System – To detect compressed air leaks. Suggested Frequency – Half-Yearly
- Periodic CAss of Transmission Towers – To detect faults like Loose Connections at joints, Tracking at insulators, Arcing & Corona. Suggested Frequency – Half-Yearly
- Periodic CAss of Steam Traps & Steam Piping – To detect faulty steam traps & even minute steam leaks. Suggested Frequency – Quarterly
- Periodic CAss of Transformers – To detect Contact Resistances Winding- insulator connections, Insufficient Oil Level, Contact Resistances at OH Cable – Insulator Connections, Tracking at Insulators, Arcing & Corona. Suggested Frequency – Monthly
- Periodic CAss of Electric Panels – To detect Contact Resistances at joints, Unbalanced load, Harmonics in the circuit, Overloading, Single Phasing, and Tracking/Arcing/corona in case of HT Panels. Suggested Frequency – Half-Yearly
- Periodic CAss of substation/ Switch Yards – To detect Contact Resistances, Tracking, Arcing, Corona in different equipment in sub-station/ switchyard. Suggested Frequency – Yearly
- Periodic CAss of Insulated Pipelines – To detect Clogging, Corrosion, Cracking, Thinning, Erosion, Leaks, Blockages, Varying fluid levels, Coking, Scale build-up, in the pipelines & also to detect insulation quality & thickness. Suggested Frequency – Half-Yearly
- Periodic CAss of Pressure Vessels – To detect minute air leaks. Suggested Frequency – Quarterly
- Periodic CAss of Heat Exchangers – To detect leaks of fluid. Suggested Frequency – Quarterly
- Periodic CAss of Boilers/ Furnaces/ Refractories – To detect Heat Loss/ Insulation Failures/ Heat Leaks. Suggested Frequency – Quarterly
- Periodic CAss of Tankers/ Containers – For tightness testing, to detect leaks. Suggested Frequency – Yearly
- Periodic CAss of Solar Panels – To detect failed solar cells in the solar panel, a solar panel in the solar array. Suggested Frequency – Quarterly